fallingAlar m — if the first sample is less
than or equal to the value set for the Falling
Threshold (see “Falling Threshold” below),
an alarm is generated.
risingOrFallingAlar m — sets both rising
and falling alarms.
Rising Threshold
Enter the number of the threshold for the sampled statistic.
When the current sampled value is greater than or equal to
this threshold, and the value at the last sampling interval
was less than this threshold, a single event will be
generated.
Falling Threshold
Enter the number of the threshold for the sampled statistic.
When the current sampled value is less than or equal to this
threshold, and the value at the last sampling interval was
greater than this threshold, a single event will be generated.
Rising Event Index
Enter the number of the Event entry that was created for
this Alarm entry.
This number references the Event entry that is to be
utilized when a rising threshold is crossed. If there is no
corresponding entry in the eventTable, or if this value is
zero, no associated event will be generated.
Falling Event Index
Enter the number of the Event entry that you created for
this Alarm entry.
This number references the Event entry that is to be
utilized when a rising threshold is crossed. If there is no
corresponding entry in the eventTable, or if this value is
zero, no associated event will be generated.
Owner String
Enter name of the person or entity who defined the entry.
3
Type y at the prompt to set the parameters.