Installation
Page 2-2
Installing the IntraSwitch
Installation
Guidelines
Before installing the IntraSwitch 5324, carefully review the
following guidelines.
Power Requirements
The source electrical outlet should be installed near the switch,
be easily accessible, and be properly grounded.
Make sure the power source adheres to the following
guidelines:
❏ Voltage range: 100 to 240 VAC
❏ Frequency range: 60/50 Hz
❏ Maximum current: 1.6 A
Environmental Requirements
The IntraSwitch must be installed in a clean, dry, dust-free area
with adequate air circulation to maintain the following
environmental limits:
❏ Temperature: 0° to 45° C
❏ Relative Humidity: 5% to 85% non-condensing
Avoid direct sunlight, heat sources, or areas with high levels of
electro-magnetic interference.
Cooling and Airflow
The IntraSwitch has two internal fans that cool the interior by
drawing air through vents on the sides and forcing heated air
out through holes in the rear.
▲ Important: Do not restrict air flow by covering
or obstructing air vents on the sides of the case.