Asus PR-DLS533 Personal Computer User Manual


 
4-26
Chapter 4: BIOS Setup
4.5.2 Hardware Monitor
MB Temperature [xxxC/xxxF]
CPU1 Temperature [xxxC/xxxF]
CPU2 Temperature [xxxC/xxxF]
The onboard hardware monitor is able to detect the MB (motherboard) and
CPU temperatures. Set to [Ignore]
only if necessary.
CPU1 Fan Speed [xxxxRPM]
CPU2 Fan Speed [xxxxRPM]
The onboard hardware monitor is able to detect the CPU fan speeds in
rotations per minute (RPM). The presence of the fans is automatically
detected.
If any of the monitored items is out of range, the following error
message appears: Hardware Monitor found an error. Enter Power
setup menu for details. You will then be prompted to Press F1 to
continue or DEL to enter SETUP.
VCORE Voltage, 3.3V Voltage, 5V Voltage, 12V Voltage
, 3VSB
Voltage
The onboard hardware monitor is able to detect the voltage output by the
onboard voltage regulators.
Make sure to connect the CPU fan cables to the appropriate
connectors (CPU1 cable to CPUFAN1 connector, CPU2 cable to
CPUFAN2 connector). Otherwise, the system may not boot.