Asus RS100-E5-PI2 Server User Manual


 
6-26 Chapter 6: RAID Conguration
3. When prompted, use the arrow keys to select Yes from the Consistency
Check dialog box, then press <Enter>. You may also press <F10> to check
the drive consistency.
A progress bar appears on screen.
4. While checking the disk consistency, press <Esc> to display the following
options.
Stop: Stops the consistency check. The utility stores the percentage
of disk checked, When you restart checking, it continues from the last
percentage completed rather than from zero percent.
Continue: Continues the consistency check.
Abort: Aborts the consistency check. When you restart checking, it
continues from zero percent.
5. When checking is complete, press any key to continue.
LSISoftwareRAIDCongurationUtilityVerA.53Sep06,2007
SPACE-(De)Select,F10-CheckConsistency
Management Menu
Congure
Initialize
Objects
Rebuild
CheckConsistency
VirtualDrive(s)Congured
LD RAID Size #Stripes StripSz Status
010154494MB464KBONLINE
Virtual Drives
Virtual Drive 0
ConsistencyCheck?
Yes
No
Select VD
LSISoftwareRAIDCongurationUtilityVerA.53Sep06,2007
SPACE-(De)Select,F10-CheckConsistency
Management Menu
Congure
Initialize
Objects
Rebuild
CheckConsistency
VirtualDrive(s)Congured
LD RAID Size #Stripes StripSz Status
010154494MB464KBONLINE
Virtual Drives
Virtual Drive 0
CC Under Process
VD0ConsistencyCheck.PressEsctoAbort.
¦
85%Completed
The Data On The Drives Is Inconsistency. Repair Done!