AudioControl VERSION 6.2 Network Router User Manual


 
SIP Release Notes 162 Document #: LTRT-26901
CPE SIP Products
3. Once SecureStartup mode is enabled, it can’t be disabled correctly thereafter.
Attempting to revert to non-Secure startup causes all parameters to return to defaults.
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410
4. The SSH session closes when issuing the cf get CLI command to write the entire
configuration file to the SSH session. A workaround for this constraint is to use the cf
view CLI command to view the configuration file with page breaks.
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410
3.7 High Availability Constraints
This release includes the following known Mediant 3000 High Availability (HA) constraints:
1. The Graceful Lock feature does not function when HA is enabled. Attempting to do so
causes errors in the Syslog.
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410
2. When using IPSec for control protocol transport, the device may experience a large
bulk of Syslog error messages during switchover. These messages can be ignored as
the switchover should succeed and the connection with the softswitch is restored.
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410