3. T310 Timer Configuration for ISDN Variant NI2:
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410
Management Protocol
Web INI
SNMP
EMS
CLI
Application
Gateway/GW SBC
SAS
The device now supports configuration of the T310 timer for the ISDN variant National
ISDN with sub variant 2 (NI2). This solution is similar to the T310 timer for DMS and
Euro ISDN. The T310 timer is the timer that is set when the ISDN interface receives a
Call Proceeding message. If no Alerting, Progress, or Connect message is received
within the duration of T310, the call clears.
The T310 timer can be configured using the existing parameter, ISDNTimerT310.
When set to 0, the timer uses the default timer according to the protocol’s
specifications.
4. Removing Validation Check of UUIE Data:
Product
MP-11x MP-124
Mediant 600 Mediant 1000
Mediant 800 MSBG Mediant 1000 MSBG
Mediant 2000
Mediant 3000/TP-6310 Mediant 3000 HA/TP-6310
Mediant 3000/TP-8410 Mediant 3000 HA/TP-8410
Management Protocol
Web INI
SNMP
EMS
CLI
Application
Gateway/GW SBC
SAS
The device now supports a bit-field that determines the behavior of the Q.931 protocol.
This is configured per trunk, using the new parameter, ISDNNSBehaviour2. The
relevant bit is NS_BEHAVIOUR2_ANY_UUI (0x0008). When this bit is set, any User to
User Information Element (UUIE) is accepted for any protocol discriminator. This
feature is useful for interoperability with non-standard switches.