Figure 2-10. Temperature System Dialog Box
Table 2-8. Temperature Threshold Parameters
Threshold Defines...
High Shutdown
Temperature
(Layer 2)/High
Warning
Temperature
(Layer 3)
The value in degrees Celsius that when passed
causes the switch to send a trap to the network
management station and triggers a shutdown.
By default, this value is 50 degrees Celsius. For
the Layer 3 CPU sensor, the default value is 100
degrees Celsius.
Upper Warning
Temperature
The value in degrees Celsius that when passed
causes the switch to send a warning that the
temperature is approaching the high
temperature threshold. By default, this value is
45 degrees Celsius. For the Layer 3 CPU sensor,
the default value is 85 degrees Celsius.
Lower Warning
Temperature
The value in degrees Celsius that when passed
causes the switch to send a warning that the
temperature is approaching the low
temperature threshold. By default, this value is
5 degrees Celsius.
Low Shutdown
Temperature
(Layer 2)/
Low Warning
Temperature
(Layer 3)
The value in degrees Celsius of how low the
temperature must drop on the switch to reset
the warning and high thresholds. This value
prevents the switch from sending traps
continually if the temperature is hovering
around the threshold value. By default, this
value is 0 degrees Celsius.