Axis Communications 700 Server User Manual


 
Appendix D: Updating the Software AXIS 700 User’s Manual
90
Updating the Flash Memory
To upgrade over the network you will need the following:
The file with the new AXIS 700 software. The name of the file is
of the form
product-version.bin, i.e. 700_1_14.bin for
software release 1.14 of the AXIS 700.
A computer on the network with TCP/IP and FTP.
Follow these steps to upgrade the AXIS 700 software:
1. Log in to the AXIS 700 with the command
ftp <IP address>
where <IP address> is the name or IP address assigned to the
AXIS 700.
2. You will be prompted for user id and password. Use the user id
root
which has the default password
pass.
3. Issue the command bin to change to binary transfer mode.
4. Issue the command
put <software name> flash where
<software name> is the name of the new software, e.g. 700-
1_14.bin.
5. During the flash load, the AXIS 700 LCD will display the message
Upgrading server” and a progress bar. Wait for the flash load to
finish. This normally takes 1 to 4 minutes. The unit will then
automatically restart with the new AXIS 700 software.
Caution! Be careful not to interrupt the file transfer. If the transfer is
interrupted, the AXIS 700 may have to be re-initialized by your
dealer.
6. Log out using the command
quit, bye or exit depending on your
FTP version.
Notes: o If you are using a window-based FTP client application such as
Ws_ftp or Fetch, you must rename the new file
<software
file> to flash before downloading.
o It is recommended to upload the current configuration before
upgrading. See “Configuring using FTP” on page 51.