AXIS 700 User’s Manual Appendix E: Technical specifications
95
Number of
Destinations
Depending on the length of the addresses, the Administrator can
define 50-100 destinations within the AXIS 700. The maximum
number is limited by the EEPROM memory. If using LDAP or
server-based address lists, the number of destinations is limited to the
available RAM.
Software Updates Flash memory allows central and remote updating of the AXIS 700
software over the network using FTP.
Hardware CPU: 32 bit RISC Controller (AXIS ETRAX)
Flash memory: 2 Mbytes
RAM: 2 Mbytes
EEPROM: 8 kbytes
Logical Connection IEEE 802.2, IEEE 802.3, SNAP and Ethernet II frame types
simultaneously.
Attachments
Network Connectors
10baseT (twisted pair) and 10base2 (thin) for Ethernet
Optional Accessories SCSI cable: 50 pin high-density shielded (micro-D)
SCSI cable: 50 pin high-density shielded to 50 pin shielded low-
density (Centronics)
Power supply 12V DC (36VA), via external power unit (AXIS PS-C) or
12V DC (13,2VA), via external power unit (AXIS PS-E)
Dimensions Height: 1.7 in (4.3 cm)
Width: 5.9 in (14.9 cm)
Depth: 8.8 in (22.4 cm)
Weight 1.5 lbs (0.7 kg)
Environmental Temperature: 40-105°F (5-40°C)
Humidity: 20-80% RHG, noncondensing
Approvals
EMC
FCC Subpart B, Class A; CE EN 55022/1994, EN 50082-1/1992.
Safety EN 60950, UL, CSA
Warranty 3 years.