Axis Communications NPS 532 Printer User Manual


 
Appendix A: The parameter list
72 Axis NPS 530/532 User’s Manual
Factory Default Settings
If you should need to reset the NPS 530/532 to factory default
conditions, the best way to do this is to use the TEST button. This
procedure involves switching the NPS 530/532 off and on. If you use an
external power supply, unplug the power cord to switch off the NPS 530/
532, otherwise use the printer’s power switch.
1. Switch off the NPS 530/532.
2. Press and hold the TEST button while you switch on the NPS 530/
532. Keep the TEST button pressed for at least 20 seconds until the
PACKET flashes with one second intervals.
3. Release the TEST button and wait at least five seconds (five indica-
tor flashes).
4. Press and hold the TEST button for at least five seconds until the
PACKET indicator remains constantly lit.
5. Restart the NPS 530/532 (power-off/power-on).
The NPS 530/532 is now reset to factory default conditions.
Note: The Node and Internet Addresses (NODE_ADDR and INT_ADDR)
remain unchanged, but all other parameters are reset to factory default
values.