Bosch Appliances X10 Network Router User Manual


 
VideoJet X10 Appendix | en 109
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
8.8 Terminal Block
The terminal block has several contacts for:
4 alarm inputs
4 relay outputs
Serial data transmission
Pin Assignment
The pin assignment of the serial interface depends on the interface mode used (see
Section 5.37 Advanced Mode: COM1, page 76).
Connect each alarm input to a ground contact (GND) when connecting alarm inputs.
For the RM1 and RM2 contact specifications, see Section Remote Indication of the Connection
Status, page 23.
For the backup power supply specifications, see Section Backup Power Supply, page 24.
Contact RS-232 mode RS-422 mode RS-485 mode
CTS CTS (clear to send) RxD- (receive data minus) Data-
TXD TxD (transmit data) TxD- (transmit data minus)
RTS RTS (ready to send) TxD+ (transmit data plus) Data+
RXD RxD (receive data) RxD+ (receive data plus)
GND GND (ground)
Contact Function
IN1 Input alarm 1
IN2 Input alarm 2
IN3 Input alarm 3
IN4 Input alarm 4
GND Ground
R1 Relay output 1
R2 Relay output 2
R3 Relay output 3
R4 Relay output 4
RM1 LED remote indicator
RM2 LED remote indicator
BP Backup power supply
GND Ground
+ 10 to 30 V (power supply)
–Ground