Bosch Appliances X10 Network Router User Manual


 
VideoJet X10 Configuration Using a Web Browser | en 73
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
5.34 Advanced Mode: Alarm Task Editor
As an alternative to the alarm settings on the various alarm pages, you can enter your desired
alarm functions in script form here. This will overwrite all settings and entries on the other
alarm pages.
1. Click the Examples link under the Alarm Task Editor field to see some script examples. A
new window will open.
2. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with
your requirements.
3. When you are finished, click the Set button to transmit the scripts to the unit. If the
transfer was successful, the message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.
!
CAUTION!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the
information in the Alarm Task Script Language document. You can find the document on the
product CD supplied (see Section 3.1 Scope of Delivery, page 11).