Bosch Appliances X10 Network Router User Manual


 
VideoJet X10 Configuration Using a Web Browser | en 55
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
1. Click one of the tabs to edit the corresponding profile.
2. If necessary, click the Default button to return all settings to their default values.
3. Click the Copy Settings button if you want to copy the currently visible settings to other
profiles. A new window will open and you can select the profiles in which you want to
copy the settings.
4. For each profile, click the Set button to save the settings in the unit.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the Pre-
alarm option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
If you select Off, no automatic recording takes place.
Standard profile
From this field, you can select the encoder profile to be used for recording (see
Section 5.19 Advanced Mode: Encoder Profile, page 47).
Pre-alarm time
You can select the required pre-alarm time from the list field.
Post-alarm time
You can select the required post-alarm time from the list field.
Post-alarm profile
You can select the encoder profile to be used for recording during the post-alarm time (see
Section 5.19 Advanced Mode: Encoder Profile, page 47).
The Standard profile option adopts the selection at the top of the page.
Alarm input / Motion alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
i
NOTICE!
You can change or add to the recording profile description on the tabs on the Recording
Scheduler page (see Section Time periods, page 58).
!
CAUTION!
You can specify limitations for overwriting older recordings in Continuous mode by
configuring the retention time (see Section 5.24 Advanced Mode: Retention Time, page 56).
i
NOTICE!
The recording profile can deviate from the standard setting Active profile and is only used
during an active recording.
i
NOTICE!
The motion alarm is configured and activated on the VCA page (see Section 5.31 Advanced
Mode: VCA Event Triggered, page 69).
The alarm inputs are configured and activated on the Alarm Inputs page (see
Section 5.35 Advanced Mode: Alarm Inputs, page 74).
The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the
alarm inputs on the VideoJet X10.