Bosch Appliances X10 Network Router User Manual


 
VideoJet X10 Installation | en 19
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
4 Installation
4.1 Preparations
The VideoJet X10 features industrial standard equipment and is therefore suitable for both
stationary installation and mobile installation in vehicles.
Please ensure the following installation conditions:
Do not install the unit close to heaters or other heat sources. Avoid locations exposed to
direct sunlight.
Allow sufficient space for running cables.
Ensure that the unit has adequate ventilation.
When making connections, use only the cables supplied or use appropriate cables
immune to electromagnetic interference.
Position and run all cables so that they are protected from damage, and provide
adequate cable strain relief where needed.
Avoid impacts, blows and severe vibrations that exceed the specification limits (see
Section 9 Specifications, page 113), as these can irreparably damage the unit.
4.2 Mounting
The VideoJet X10 can be permanently mounted to walls, below ceilings or other load-bearing
locations using the four drillings in the unit's base.
!
CAUTION!
The unit is intended for use indoors or in housings.
Select a suitable location for installation that guarantees to meet the environmental
conditions. The ambient temperature must be between –30 and +60 °C (–22 and +140 °F).
The relative humidity must not exceed 95%.
The VideoJet X10 generates heat during operation, so you should ensure that there is
adequate ventilation and enough clearance between the unit and heat-sensitive objects or
equipment.
!
CAUTION!
The front panel of the VideoJet X10 (video input) must not be pointing upwards, as internal
heat dissipation is not guaranteed in this position. All other installation positions are
permitted.
Make sure that the mounting location (for example wall or ceiling) can reliably hold the unit.
The load bearing capacity must be adequate for four times the weight of the unit.
For mounting on metal, use screws with the following minimum specification:
M4 × 8, 8.8, DIN ISO 4017.
For mounting on concrete, use screws with the following minimum specification:
M4 × 40 mm (1.57 in) and 6 mm (0.23 in) plastic dowels, for example fischer S4, type 50106.