Bosch Appliances X10 Network Router User Manual


 
VideoJet X10 Configuration Using a Web Browser | en 75
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
Off
Relay is not triggered by events
Connection
Trigger whenever a connection is made
Video alarm
Trigger by interruption of the video signal
Motion alarm
Trigger by motion alarm, as configured on the VCA page (see Section 5.31 Advanced
Mode: VCA Event Triggered, page 69)
Local input
Trigger by the corresponding external alarm input
Remote input
Trigger by remote station's corresponding switching contact (only if a connection exists)
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. The Livepage can also be configured to display the name under the relay icon.
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
i
NOTICE!
The numbers in the lists of selectable events relate to the corresponding connections on the
unit, Video alarm 1, for example to the Video In connection.