Bosch Appliances X10 Network Router User Manual


 
38 en | Configuration Using a Web Browser VideoJet X10
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
5. Now click the OK button to apply the selected characters to the second line of the
Camera 1 parameters. The window will close.
Initiator extension
You can attach your own text to the initiator name of the VideoJet X10 to make the unit easier
to identify in large iSCSI systems. This text is added to the initiator name, separated from it by
a full stop. You can see the initiator name in the system overview (see Section 5.9 Basic Mode:
System Overview, page 36).
5.11 Advanced Mode: Password
A VideoJet X10 is generally protected by a password to prevent unauthorized access to the
unit. You can use different authorization levels to limit access.
Password
The VideoJet X10 operates with three authorization levels: service, user and live.
The highest authorization level is service. After entering the correct password, you can access
all the functions of the VideoJet X10 and change all configuration settings.
With the user authorization level, you can operate the unit and also control cameras, for
example, but you cannot change the configuration.
The lowest authorization level is live. It can only be used to view the live video image and
switch between the different live image displays.
You can define and change a password for each authorization level if you are logged in as
service or if the unit is not password protected.
Enter the password for the appropriate authorization level here.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
i
NOTICE!
Proper password protection is only guaranteed when all higher authorization levels are also
protected with a password. If a live password is assigned, for example, a service and a user
password must also be set. When assigning passwords, you should therefore always start
from the highest authorization level, service, and use different passwords.