16
CHAPTER TWO
Connect the Power Cord
When you connect the power, the screen displays 01/01 00:00 FAX.
NOTICE:
1) This fax must be earthed using a 3-pin plug.
2) Since the machine is earthed through the power outlet, you can
protect yourself from potentially hazardous electrical conditions on
the telephone network by keeping the power to your machine on
when you connect it to a telephone line. Similarly, you can protect
yourself when you want to move your machine, by disconnecting the
telephone line first, and then the power cord.
3) Lightning and power surges can damage this product! We
recommend that you use a quality surge protection device on the AC
power line as well as on the telephone line, or unplug the lines during
a lightning storm.
IMPORTANT:
If you need to remove the moulded mains plug in order to
fit an appropriate type, you must discard the moulded plug
immediately having cut it off, in order that it is not
inadvertently inserted into a live socket, thus presenting a
shock hazard. The wires in the mains lead of this
appliance are coloured in accordance with the following
code.
Green-and-yellow : Earth
Blue : Neutral
Brown : Live
As the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green-and-yellow must be
connected to the terminal in the plug which is marked by
the letter “E” or by the safety earth symbol
or coloured
green or green-and-yellow.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter “N” or coloured
black.
The wire which is coloured brown must be connected to
the terminal which is marked with the letter “L” or coloured
red.
Connect the Telephone Line
Connect one end of the telephone line cord to the jack labelled LINE on
the left side of the machine. Connect the other end to a wall jack.