Brother HL-2400Ce Printer User Manual


 
USER’S GUIDE
5-10
4. Take the Fuser Cleaner out of the Fusing Unit by holding the handle
of the Fuser Cleaner as shown below:
Fig. 5-9 Removing the Fuser Cleaner
5. Install the new Fuser Cleaner into the guide with the roller side facing
you.
Fig. 5-10 Installing the Fuser Cleaner
6. Lock the Fuser Cleaner with the Oil Bottle Lock Levers.
7. Close the Top Cover.
8. Press the
Power
button and turn the printer On.
9. Press the
Sel
button and take the printer Off Line.
10. Press the
Reset
button while holding down the
Shift
button.
11. When you see “RESET PRINTER” on the LCD panel, press the
(UP) or (DOWN) button and select “RESET PARTS LIFE”. Press
the
Set
button and select “FC ROLLER” with the (UP) or
(DOWN) button.
12. Press the
Set
button, the printer is now On Line.