Cabletron Systems 6A000/ZX-250 Network Cables User Manual


 
SmartCell 6A000/ZX-250 Reference Manual 2-81
Console Commands
LECSTLVParam
Use LECSTLVParam (LAN emulation configuration server type, length, and value parameters) to remove a specific
TLV parameter from the TLV set on the LECS.
Operator
delete
Parameters
Description
Examples
The
show lecstlvset
example is used here to show how
delete lecstlvparam
works. Observe that [2] in
show
lecstlvset
is [Max Unknown Frame Time]. That is why [Max Unknown Frame Time] appears in
delete
lecstlvparam
when “2” is entered at the [TLVIndex] prompt.
SERVER SVC
X
Input Parameter Description Value/Field Size Default
[TLVSetNumber] Number that identifies TLV parameters set in the
LECS.
1-32767 1
[TLVIndex] Number that identifies the specific TLV in the TLV
set.
1-15 1
Operator Parameters/Permissions Description
delete
lecstlvpara
m
[TLVSetNumber] <tlvsetnumber>
[TLVIndex] <tlvindex>
Administrator
Removes a TLV parameter from a TLV set on the LECS. Use
show lecstlvset before entering this command, so you know
the index number of the TLV parameter you want to delete.