Cabletron Systems 6A000/ZX-250 Network Cables User Manual


 
SmartCell 6A000/ZX-250 Reference Manual 2-41
Console Commands
ELAN
Use ELAN (emulated local area network) to create or delete ELANs on the switch. This is a quick configuration
method of managing ELAN server entries within one command. For details of how to create or delete these entries
individually, see “BUSELAN”, “LECSELAN”, and “LESELAN”.
Operators
add, delete, show
Parameters
SERVER SVC
X
Input Parameter Description Value/Field Size Default
[ELANNumber] Number of ELAN to which the BUS (broadcast
and unknown server), LECS (LAN emulation
configuration server) or LES (LANE server)
belong.
0-127 0
[ELANName] Name of ELAN to which the LES or BUS
belongs.
Up to 32 characters ELAN000
[ConnectMethod] Type of connection used. PVC, SVC SVC
[ELANType] Data-link type used by the ELAN. 802.3 (Ethernet)
802.5 (TokenRing)
802.3
[Multipoint] Indicates whether control distribute VCC is
PMP (point-to-multipoint) or PTP
(point-to-point).
YES: VCC is PMP NO:
VCC is PTP
YES
[MTU] Maximum transfer unit for the clients joining
this ELAN.
1516 or 9234 (Ethernet),
4544 (Token Ring)
1516
[Distribute] LES establishes control distribute VCC to all
the clients if distribute is ALL. If distribute is
PROXY, LES establishes control distribute
VCC only to proxy clients.
ALL, PROXY PROXY