Cabletron Systems 6A000/ZX-250 Network Cables User Manual


 
2-84 SmartCell 6A000/ZX-250 Reference Manual
Console Commands
[ArpResponseTime] Maximum time that the LEC expects a
request/response cycle to take.
seconds/1-30 n/a
[FlushTimeout] Time limit on flush response after flush
request has been sent, before taking
recovery action.
seconds/1-4 n/a
[PathSwitchingDelay] Time since sending a frame to the LECS
after which the LANE client may assume
that the frame has been either discarded or
delivered to the recipient.
seconds/1-8 n/a
[LocalSegId] Segment ID of the ELAN. seconds/0-4095 n/a
[MulticastSendVCCType] Signaling parameter used by the LEC when
establishing multicast send VCC.
0-2 n/a
[MulticastSendVCCAvgRate] Signaling parameter used by the LEC when
establishing multicast send VCC.
cells p/second/
0-370370
n/a
[MulticastSendVCCPeakRate] Signaling parameter used by the LEC when
establishing multicast send VCC.
cells p/second/
0-370370
n/a
[ConnectionCompeteTime] Time period in which data or a message is
expected from a calling party when
establishing a connection.
seconds/
1-10
n/a
Parameter Description Value/Field Size Default