SmartCell 6A000/ZX-250 Reference Manual 2-113
Console Commands
[Quiet mode] Suppresses the printing of messages to the console
but continues to forward messages to clients.
ON/OFF ON
[Start record] Starting record for message range. Log trace prints
messages within specified range. If both starting and
ending record numbers are set to infinity, log trace
captures all messages. All messages are always sent
to the client. However, console messages can be
filtered by setting the log trace flags on the switch.
5 characters infinity
[Timestamp inactive] Indicates how the time stamp will print on log
messages. In absolute <ABS> mode, the system up
time is used (this resets to 0 at each reboot). In
relative <REL> mode, you can specify a start time
by setting the timestamp to 0. In delta <DEL> mode,
the time difference between successive log messages
is printed.
ABS, REL, DEL flag=0
[Filter Flags] Limits printed messages to the designated message
type. Filter flag values are bitmapped, however,
enabling you to also print a combination of message
types by specifying alternate values. For example,
by entering 13, you can display messages that have
error, critical or emergency flags (13= 8 + 4 + 1). See
the following table:
See table below n/a
Table 2-1 Filter Fla
g
s
MESSAGES PRINTED VALUE
All messages printed 0
Emergency messages only 1
Alert messages only 2
Critical messages only 4
Error messages only 8
Warning messages only 16
Parameter Description Value/Field Size Default