Cabletron Systems 6A000/ZX-250 Network Cables User Manual


 
2-42 SmartCell 6A000/ZX-250 Reference Manual
Console Commands
Descriptions
Output Parameter Description
[LES Address] ATM address of the LANE server.
[Distribute VPI/VCI] VPI/VCI values of the control direct VCC or multicast send VCC.
[Distribute Method] Indicates whether the control distribute VCC is established for ALL clients or only
PROXY clients.
[LAN Type] Type of ELAN.
[BUSATMAddress] ATM address of the BUS (specify when the LES and BUS are not co-located).
Operator Parameters/Permissions Description
add elan [ELANNumber] <elannumber>
[ELANName] <elanname>
[ConnectMethod] <connectmethod>
[ELANType] <elantype>
[Multipoint] <distributevcctype>
[MTU] <maximumframesize>
[Distribute]
<controldistributevccoption>
Administrator
Quickly configures the switch. This command adds the
ELAN entry in all three databases (BUSELAN,
LESELAN, and LECSELAN) and activates the ELAN.
delete elan [ELANNumber] <elannumber>
Administrator
Quickly configures the switch. This removes a specific
ELAN. This command first checks that all servers
(LECS, LES, and BUS) exist before deleting any of
them.
show elan [ELANNumber] <elannumber>
All
Displays an ELAN created by either the quick
add elan
or the multiple set of commands to add an ELAN. There
might not be LECS information (as seen in the first
example) if the ELAN was created by
add buselan, and
add leselan and add lecselan had not been completed.
The LECS information is displayed if you use
add elan
or if not, after you enter
add lecselan (as seen in the
following B example below).