Cabletron Systems HSIM-A6DP- Switch User Manual


 
Chapter 3: Local Management
3-12 HSIM-A6DP User’s Guide
3.7 THE ADD/DELETE ENTRY SCREEN
To access the Add/Delete Entry screen from the ATM Connection Setup
screen perform the following steps:
1. Use the arrow keys to highlight the ADD/DELETE command at the
bottom of the ATM Connection Setup screen.
2. Press ENTER, the Add/Delete Entry screen, Figure 3-5, displays.
Figure 3-5 The Add/Delete Entry Screen
3.7.1 Add/Delete Entry Screen Fields
VPI (Modifiable)
This field is used to enter the Virtual Path Identifier of the PVC. The
available range for this field is 0 or 1, with a default value of 0.
VCI (Modifiable)
This field is used to enter the Virtual Channel Identifier of the PVC. The
available range for this field is 32 through 1020.
AAL Type (Read-Only)
This field displays the ATM Adaptation Layer (AAL) being used by the
PVC. The HSIM-A6DP uses AAL 5.
INTERFACE 25 ATM Add/Delete Entry
Device Name:6E132-25
Slot Number: X
Flash Image Revision: XX.XX.XX
BOOTPROM Revision:XX.XX.XX
RETURN
VPI VCI AAL Type Encapsulation Type
0 0 [ 5 ] VC Mux 802.3 Bridged
ADD/MODIFY EXIT
6E132-25 LOCAL MANAGEMENT