Cabletron Systems STS16-20R Switch User Manual


 
152
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide Switch Configuration
Reset Screen
To open this screen, select
Reset...
in the main menu. This screen displays the reset
options available with the switch.
Number of Resets Since Diagnostics
Number of times the switch has been reset since the switch was powered on or ran
power-on diagnostics. This is an informational heading; the data cannot be changed.
This number is not reset to 0 when nonvolatile RAM is cleared.
The following four items within the
Reset
screen are command functions that you
can select and initiate by moving the highlight over the item and pressing
ENTER.
Reset Switch With Diagnostics
A reset function is initiated with this command. It resets the switch hardware; runs
diagnostic tests; clears all counters, including address tables; and restarts the
SmartStack STS16-20D/STS16-20R. When the SmartStack STS16-20D/STS16-
20R reboots, administrative parameters from nonvolatile memory are used to
initialize the operational parameters. This takes approximately 4 to 5 minutes.
Reset Switch Without Diagnostics
This command resets the switch hardware; clears all counters, including address
tables; and starts the SmartStack STS16-20D/STS16-20R. When the SmartStack
STS16-20D/STS16-20R reboots, administrative parameters from nonvolatile
memory are used to initialize the operational parameters. This procedure takes
approximately 40 seconds.