Cabletron Systems STS16-20R Switch User Manual


 
217
Troubleshooting SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
2. Reset the switch by disconnecting the power cord, waiting 10 seconds, and then
reconnecting it to the electrical outlet. If the problem goes away, resume using
the switch.
3. If you have just downloaded new microcode, clear NVRAM and reset the
switch using the instructions in Reset Screen on page 152.
Note:
Clearing NVRAM returns all configuration parameters to their default
values.
If the problem is corrected, resume using the switch.
4. One or more bad ports can cause this symptom, and the remaining ports might
continue to operate.
Reset the switch and monitor the diagnostic messages that appear for port
failures. The section Diagnostic Screen on page 73 includes a sample
diagnostic screen. Try to correct any individual port problems that are
detected.
If the problem is corrected, resume using the switch.
5. If the problem does not go away, the problem is in the switch.
Procedure C
Use this procedure if all devices connected to the switch are having communication
problems, the ERR LED is off, and the PWR LED is on:
1. Reset the switch by disconnecting power cord for 10 seconds.
If the problem goes away, resume using the switch.
If the status LEDs indicate a failure, go to Procedure B.
If the problem persists, check all the configuration parameters.
If the problem has still not been resolved, go to Procedure D and try to
get individual ports working.
Procedure D
Use this procedure if one device connected to the switch is having a communication
problem. The ERR LED and the DIAG LEDs are off, and other attached devices
can communicate through the switch:
1. Check the port LEDs.
If the port INSRT LED is on, the problem is probably external to the
switch. Go to Step 2.