Cisco Systems 270 Switch User Manual


 
100
5. Use the show diag fru-error command to display any errors that appear in the result-string.
Example
6. Reboot the chassis when the self-test is complete.
Example
Run a Rack Locator Test
The rack locator test causes the LEDs on the tested chassis to blink for the duration of the test. To run a
rack locator test, perform the following steps:
1. Start the test. The LEDs of the Server Switch begin to blink.
Example
2. Stop the test. The LEDs return to normal functions.
Example
SFS-270# show diag fru-error
================================================================
Fru-Error
================================================================
fru-slot fru-error
----------------------------------------------------------------
card(9) none
card(10) none
card(11) none
card(12) none
card(13) none
card(14) none
card(15) none
card(17) none
fan(1) none
fan(2) none
fan(3) none
fan(4) none
power-supply(1) none
power-supply(2) none
SFS-270#
SFS-270# reload
System configuration is modified. Save? [yes(default) | no | filename] y
Proceed with reload? [yes(default) | no] y
TS270-1> enable
TS270-1# configure terminal
TS270-1(config)# diagnostic rack-locator
TS270-1(config-diag-rack-locator-1)# start
TS270-1(config-diag-rack-locator-1)# stop