Cisco Systems 270 Switch User Manual


 
102
You can also view POST error codes with the show diagnostic post command. This command displays
the results of each POST that executed at power-on.
Example
To view FRU errors on your Topspin 270/Cisco SFS 7008, enter the show diagnostic fru-error
command.
Example
The following types of hardware errors are logged for the Topspin 270/Cisco SFS 7008 power supply:
SFS-270# show diagnostic post
================================================================================
Post Status
================================================================================
fru-slot post-status error-codes
--------------------------------------------------------------------------------
card(1) failed 1:0:0:0
fan(1) passed 0:0:0:0
fan(2) passed 0:0:0:0
power-supply(1) passed 0:0:0:0
SFS-270# show diagnostic fru-error
================================================================================
Fru-Error
================================================================================
fru-slot fru-error
--------------------------------------------------------------------------------
card(1) _FRU_POWER_CONTROLLER_CONFIG_ERR
fan(1) none
fan(2) none
power-supply(1) none
Table 6-1: Topspin 270/Cisco SFS 7008 Power Supply Errors
Error Number Description
1 Power Supply DC Fail Error
2 Power Supply Fan Fail Error
3 Power Supply I2C Communication Error