Cisco Systems SG50028PK9NA Switch User Manual


 
Security
Configuring TACACS+
336 Cisco Small Business 200, 300 and 500 Series Managed Switch Administration Guide (Internal Version)
18
Source IPv4 —(In Layer 3 system mode only) Select the device IPv4
source interface to be used in messages sent for communication with the
TAC AC S+ se r ve r.
Source IPv6 —(In Layer 3 system mode only) Select the device IPv6
source interface to be used in messages sent for communication with the
TAC AC S+ se r ve r.
NOTE If the Auto option is selected, the system takes the source IP address
from the IP address defined on the outgoing interface.
STEP 4 Click Apply. The TACACS+ default settings are added to the Running
Configuration file. These are used if the equivalent parameters are not defined in
the Add page.
STEP 5 To add a TACACS+ server, click Add.
STEP 6 Enter the parameters.
Server Definition—Select one of the following ways to identify the
TAC AC S+ se r ve r :
- By IP Address—If this is selected, enter the IP address of the server in
the Server IP Address/Name field.
- By Name—If this is selected enter the name of the server in the Server IP
Address/Name field.
IP Version—Select the supported IP version of the source address: IPv6 or
IPv4.
IPv6 Address Type—Select the IPv6 address type (if IPv6 is used). The
options are:
- Link Local—The IPv6 address uniquely identifies hosts on a single
network link. A link local address has a prefix of FE80, is not routable, and
can be used for communication only on the local network. Only one link
local address is supported. If a link local address exists on the interface,
this entry replaces the address in the configuration.
- Global—The IPv6 address is a global Unicast IPV6 type that is visible and
reachable from other networks.
Link Local Interface—Select the link local interface (if IPv6 Address Type
Link Local is selected) from the list.
Server IP Address/Name—Enter the IP address or name of the TACACS+
server.