fn=65 Function 65 Erasing All Data of NV Graphics in a Lump
GS ( L pL pH m fn d1 d2 d3
[Code] <1D>H<28>H<4C>H<pL><pH><m><fn><d1><d2><d3>
[Range] (pL+pH×256)=5(pL=5pH=0)
m=48
fn=65
d1=67(“C”)
d2=76(“L”)
d3=82(“R”)
[Outline] [The specification which is common to the model]
Erases all defined data of NV graphics in a lump.
fn=66 Function 66 Erasing Specified NV Graphics Data
GS ( L pL pH m fn kc1 kc2
[Code] <1D>H<28>H<4C>H<pL><pH><m><fn><kc1><kc2>
[Range] (pL+pH×256)=4(pL=4pH=0)
m=48
fn=66
32kc1126
32kc2126
[Outline] [The specification which is common to the model]