- 183 -
CT-S300/CT-S310
• a = 3: When paper width is specified
Setting Status Sending Data
Stored
Value
Paper Width 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1 58mm 49(“1”) ― ― ― ―
3 80mm 51(“3”) ― ― ― ―
• a = 5: When print density is specified
Setting Status Sending Data
Stored
Value
Print Density 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
65530 70% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 48(“0”)
65531 75% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 49(“1”)
65532 80% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 50(“2”)
65533 85% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 51(“3”)
65534 90% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 52(“4”)
65535 95% 54(“6”) 53(“5”) 53(“5”) 51(“3”) 53(“5”)
0 Basic density 48(“0”) ― ― ― ―
1 105% 49(“1”) ― ― ― ―
2 110% 50(“2”) ― ― ― ―
3 115% 51(“3”) ― ― ― ―
4 120% 52(“4”) ― ― ― ―
5 125% 53(“5”) ― ― ― ―
6 130% 54(“6”) ― ― ― ―
7 135% 55(“7”) ― ― ― ―
8 140% 56(“8”) ― ― ― ―
• a = 6: When printing speed is specified
Setting Status Sending Data
Stored
Value
Print Speed 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1 Speed level 1 49(“1”) ― ― ― ―
2 Speed level 2 50(“2”) ― ― ― ―
3 Speed level 3 51(“3”) ― ― ― ―
4 Speed level 4 52(“4”) ― ― ― ―
5 Speed level 5 53(“5”) ― ― ― ―
6 Speed level 6 54(“6”) ― ― ― ―
7 Speed level 7 55(“7”) ― ― ― ―
8 Speed level 8 56(“8”) ― ― ― ―
9 Speed level 9 57(“9”)
• a = 97: When number of divisions for head conducting is specified
Setting Status Sending Data
Stored
Value
No. of
Divisions
1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
2
2 division
conducting
50(“2”) ― ― ― ―
4
4 division
conducting
52(“4”) ― ― ― ―
• a = 116: When kind of paper is specified
Setting Status Sending Data
Stored
Value
Print Control 1st Byte 2nd Byte 3rd Byte 4th Byte 5th Byte
1
Single-color
paper
49(“1”) ― ― ― ―
2 2-color paper 50(“2”) ― ― ― ―