Citizen Systems CT-S2000 Printer User Manual


 
- 226 -
ESC p m n1 n2
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 CT-S310
support model
PMU2XXX
[Function] Generating the specified pulses
[Code] <1B>H<70>H<m><n1><n2>
[Range] m=014849
0n1n2255
[Outline] [The specification which depend on the model]
• The signals specified by “n1” and “n2” are output to the connector pin specified by “m”.
• “m” has the followings.
m Connector Pin
0, 48 Drawer kick-out pin No. 2
1, 49 Drawer kick-out pin No. 5
• The ON time is n1 x2 ms, and OFF time n2 x2 ms.
[Caution] • When “m” is beyond a definition range, no signal is output, discarding “n1” and “n2”.
• The drawer drive duty must be within the following range:
ON time
ON timeOFF time
0.2
(The OFF time should be 4 times or more longer than the ON time.)
[Sample Program]
LPRINT CHR$(&H1B) + "p"
LPRINT CHR$(0); ・・・・・ Selects pin No. 2.
LPRINT CHR$(5); ・・・・・ Sets ON time to 10 ms
LPRINT CHR$(50); ・・・・・ Sets OFF time to 100 ms