Dell A03 Server User Manual


 
About Your System 35
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
The DIMM in slot "##"
has had a multi-bit error
(MBE).
See "Troubleshooting
System Memory."
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log anymore SBEs until
the system is rebooted.
"##" represents the DIMM
implicated by the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC
The system BIOS has
disabled memory mirroring
because it has determined
one half of the mirror has
had too many errors. "##
& ##" represents the
DIMM pair implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
I1910 Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1911 LCD Log full.
Check SEL to
review all
Errors.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912 SEL full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for details
of the error messages,
then clear the SEL.
Table 1-1. LCD Status Messages (continued)
Code Text Cause Corrective Actions