Dell M620 Server User Manual


 
Error Code Message Information
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1360
Message A bus fatal error was detected on a component at slot <
number
>.
LCD Message Bus fatal error on slot <
number
>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1362
Message Bus performance degraded for a component at slot <
number
>.
Details System performance may be degraded. The bus is not operating at
maximum speed or width.
Action Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.
PCI2000
Message A fatal IO error detected on a component at bus
<
bus
>device<
device
>function <
func
>.
LCD Message Fatal IO error on bus <
bus
> device <
device
> function <
func
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, remove and reinstall
the device.
PCI2002
Message A fatal IO error detected on a component at slot <
number
>.
LCD Message Fatal IO error on slot <
number
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, remove and reinstall
the device.
PCI3000
Message Device option ROM on embedded NIC failed to support Link Tuning or
FlexAddress.
Details Either the BIOS, BMC/iDRAC, or LOM firmware is out of date and does
not support FlexAddress.
Action Update BIOS, BMC/iDRAC, and LOM firmware. If the issue persists,
see Getting Help.
PCI3002
Message Failed to program virtual MAC address on a component at bus
<
bus
>device<
device
>function <
func
>.
101