Dell M620 Server User Manual


 
Error Code Message Information
LCD Message System inlet <
name
> temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0122
Message The system inlet temperature is outside of range.
LCD Message System inlet <
name
> temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event log for fan
failures.
TMP0100
Message Disk drive bay temperature is less than the lower warning threshold.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0104
Message Disk drive bay temperature is less than the lower critical threshold.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0126
Message Disk drive bay temperature is greater than the upper warning
threshold.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0128
Message Disk drive bay temperature is outside of the allowable range.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event log for fan
failures.
126