Dell M620 Server User Manual


 
Error Code Message Information
SEC0033
Message The chassis is open while the power is off.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis was opened while the power was off. System security
may have been comprised.
Action Close the chassis and verify hardware inventory. Check system logs.
SEC0040
Message A critical stop occurred during OS load.
Details Operating system generated critical stop IPMI event. (Sensor type
code = 20H)
Action Check video and operating system logs for additional information
SEC0041
Message BIOS detected an error configuring the Intel Trusted Execution
Technology (TXT).
LCD Message BIOS detected an error configuring TXT. Check system configuration.
Details TXT initialization failure. System configuration may have changed.
Action Check system hardware inventory and software configuration.
SEC0042
Message Processor detected an error while performing an Intel Trusted
Execution Technology (TXT) operation.
LCD Message CPU detected an error while performing a TXT operation. Check
system configuration.
Details TXT CPU microcode boot failure. System configuration may have
changed.
Action Check system hardware inventory and software configuration.
SEC0043
Message BIOS Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error during POST.
LCD Message BIOS detected a TXT error during POST. Check system configuration.
Details TXT Post failure. System configuration may have changed.
Action Check system hardware inventory and software configuration.
SEC0044
Message SINIT Authenticated Code Module detected an Intel Trusted
Execution Technology (TXT) error at boot.
LCD Message SINIT detected a TXT error at boot. Check system configuration.
Details TXT initialization failure. System configuration may have changed.
117