Dell M620 Server User Manual


 
Error Code Message Information
HWC4000
Message A hardware incompatibility detected between BMC/iDRAC firmware
and CPU.
LCD Message Incompatibility between BMC/iDRAC firmware and CPU. Update
firmware.
Details A hardware incompatibility was detected between BMC/iDRAC
firmware and Processor(s). An iDRAC or BMC firmware update is
needed.
Action Update the BMC/iDRAC firmware. If the issue persists, see Getting
Help.
HWC4002
Message A hardware incompatibility detected between BMC/iDRAC firmware
and other hardware.
Details A hardware incompatibility was detected between BMC/iDRAC
firmware and other hardware. An iDRAC or BMC firmware update is
needed.
Action Update the BMC/iDRAC firmware. If the issue persists, see Getting
Help.
HWC4011
Message Hardware unsuccessfully updated for mezzanine card <
number
>.
Action Check presence of the hardware, reinstall or reconnect, then
reattempt the update. If the issue persists, see Getting Help.
HWC4013
Message Hardware unsuccessfully updated for embedded NIC.
Action Check presence, reinstall or reconnect, then reattempt the update. If
the issue persists, see Getting Help.
HWC4015
Message Link Tuning error detected.
Details CMC has old firmware. After updating the firmware the CMC will
recognize the device.
Action Update the CMC firmware. If the issue persists, see Getting Help.
HWC5001
Message <
name
> is offline.
Action If unexpected, check presence, then reinstall or reconnect.
HWC5002
Message A fabric mismatch detected on <
name
>.
Details The fabric type for the IOM and mezzanine cards must match.
89