Dell M620 Server User Manual


 
Error Code Message Information
Action Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.
PDR0001
Message Fault detected on drive <
number
>.
LCD Message Fault detected on drive <
number
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting
Help.
PDR0002
Message A predictive failure detected on drive <
number
>.
Details The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR0016
Message Drive <
number
> is removed.
LCD Message Drive <
number
> is removed. Check drive.
Details The controller detected a drive removal.
Action If unintended, verify drive installation. Remove and re-seat the
indicated disk. If the issue persists, see Getting Help.
PDR1001
Message Fault detected on drive <
number
> in disk drive bay <
bay
>.
LCD Message Fault detected on drive <
number
> in disk drive bay <
bay
>. Check
drive.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Re-seat the failed drive. If the issue persists, see Getting Help.
PDR1002
Message A predictive failure detected on drive <
number
> in disk drive
bay<
bay
>.
Details The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR1016
Message Drive <
number
> is removed from disk drive bay <
bay
>.
LCD Message Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
103