Error Code Message Information
Action Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.
PDR0001
Message Fault detected on drive <
number
>.
LCD Message Fault detected on drive <
number
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting
Help.
PDR0002
Message A predictive failure detected on drive <
number
>.
Details The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR0016
Message Drive <
number
> is removed.
LCD Message Drive <
number
> is removed. Check drive.
Details The controller detected a drive removal.
Action If unintended, verify drive installation. Remove and re-seat the
indicated disk. If the issue persists, see Getting Help.
PDR1001
Message Fault detected on drive <
number
> in disk drive bay <
bay
>.
LCD Message Fault detected on drive <
number
> in disk drive bay <
bay
>. Check
drive.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Re-seat the failed drive. If the issue persists, see Getting Help.
PDR1002
Message A predictive failure detected on drive <
number
> in disk drive
bay<
bay
>.
Details The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR1016
Message Drive <
number
> is removed from disk drive bay <
bay
>.
LCD Message Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
103