Error Code Message Information
MEM1012
Message Memory device at location <
location
> is in a degraded state.
Details The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1016
Message Memory device at location <
location
> is not installed correctly.
LCD Message Memory <
location
> is not installed correctly. Reinstall.
Details The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM1205
Message Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
LCD Message Memory mirror lost on <
location
>. Power cycle system.
Details The memory may not be seated correctly, misconfigured, or has
failed.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM1206
Message Memory mirror redundancy is degraded. Check memory device at
location <
location
>.
Details The memory may not be seated correctly, misconfigured, or has
failed.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM1208
Message Memory spare redundancy is lost. Check memory device at location
<
location
>.
LCD Message Memory spare lost on <
location
>. Power cycle system.
Details Memory sparing is no longer available.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1212
Message Memory redundancy is lost.
Details The memory may not be seated correctly, misconfigured, or has
failed.
95