Dell R220 Server User Manual


 
Error Code Message Information
ASR0003
Message The watchdog timer power cycled the system.
Details The operating system or an application failed to
communicate within the time-out period. The system was
power-cycled.
Action Check the operating system, application, hardware, and
system event log for exception events.
BAT0002
Message The system board battery has failed.
Details The system board battery is either missing or bad.
Action See Getting Help.
BAT0017
Message The <name> battery has failed.
Details The <name> battery is either missing, bad, or unable to
charge due to thermal issues.
Action Check system fans. If the problem persists, see Getting Help.
CPU0000
Message CPU <number> has an internal error (IERR).
Details System Event Log and Operating System Logs may indicate
that the exception is external to the processor.
Action Review System Event Log and Operating System Logs. If the
issue persists, see Getting Help.
CPU0001
Message CPU <number> has a thermal trip (over-temperature) event.
Details The processor temperature increased beyond the
operational range.
Action Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see Getting Help.
CPU0005
Message CPU <number> configuration is unsupported.
Details System is unable to boot or may run in a degraded state.
Action Review the technical specifications for supported processor
types.
CPU0010
Message CPU <number> is throttled.
Details The CPU is throttled due to thermal or power conditions.
83