Error Code Message Information
SEC0033
Message The chassis is open while the power is off.
Details The chassis was opened while the power was off. System
security may have been compromised.
Action Close the chassis and verify hardware inventory. Check
system logs.
SEL0006
Message All event logging is disabled.
Details This message is displayed when all event logging has been
disabled by the user.
Action If unintended, re-enable logging.
SEL0008
Message Log is full.
Details When the event log is full, additional events are not written
to the log. Older events may be overwritten and lost. This
message may also appear if the user disabled event logging.
Action Backup and clear log.
SEL0012
Message Could not create or initialize the system event log.
Details If the system event log fails to initialize, platform status and
failure events are not captured. Some management software
do not report platform exceptions.
Action Reboot the management controller or iDRAC. Cycle system
input power. If problem persists call support.
SEL1204
Message An unknown system hardware failure detected.
Details If the system event log failed to initialize, platform status and
failure events are not captured. Some management software
do not report platform exceptions.
Action Re-configure system to the minimum supported
configuration. If issues persists, contact support.
TMP0118
Message The system inlet temperature is less than the lower warning
threshold.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
90