Dell R420xr Personal Computer User Manual


 
NOTE: In some messages, a particular system component is identified by name (“<name>”)
component number (“<number>”), or location (“bay”).
Error Code Message Information
AMP0302
Message The system board <name> current is greater than the upper
warning threshold.
Details System board <name> current is outside of the optimum
range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
AMP0303
Message The system board <name> current is greater than the upper
critical threshold.
LCD Message System board <name> current is outside of range.
Details System board <name> current is outside of the optimum
range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
ASR0000
Message The watchdog timer expired.
Details The operating system or an application failed to
communicate within the time-out period.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0001
Message The watchdog timer reset the system.
Details The operating system or an application failed to
communicate within the time-out period. The system was
reset.
Action Check the operating system, application, hardware, and
system event log for exception events.
ASR0002
Message The watchdog timer powered off the system.
111