Error Code Message Information
LCD Message PSU wattage mismatch; PSU <number> = <value >watts
Details Power supplies should be of the same input type and power
rating.
Action Install matched power supplies and review this manual for
proper configuration.
PSU1201
Message Power supply redundancy is lost.
Details The power supply tries to operate in a degraded state.
System Performance and power redundancy may be
degraded or lost.
Action Check input power. Reinstall the power supply. If the issue
persists, see Getting Help.
PSU1204
Message The power supplies are not redundant. Insufficient resources
to maintain normal operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Action Check the event log for power supply failures. Review
system configuration and power consumption.
PWR1004
Message The system performance degraded because power capacity
has changed.
Details The system may power down or operate in a performance
degraded state.
Action Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.
PWR1005
Message The system performance degraded because the user-
defined power capacity has changed.
Details The user-defined power settings have affected system
operation.
Action If unintended, review system configuration changes and
power policy.
PWR1006
Message The system halted because system power exceeds capacity.
123