Dell R420xr Personal Computer User Manual


 
Error Code Message Information
MEM8000
Message Correctable memory error logging disabled for a memory
device at location <location>.
LCD Message SBE log disabled on <location>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. Reinstall
memory at location <location>.
PCI1302
Message A bus time-out was detected on a component at bus <bus>
device<device> function <func>.
Details System performance may be degraded. The device has failed
to respond to a transaction.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1304
Message An I/O channel check error was detected.
LCD Message I/O channel check error detected. Power cycle system.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1308
Message A PCI parity error was detected on a component at bus
<bus>device<device>function <func>.
LCD Message PCI parity error on bus <bus> device <device> function
<func>. Power cycle system.
Details System performance may be degraded, PCI device may fail
to operate, or system may fail to operate.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1320
Message A bus fatal error was detected on a component at bus
<bus>device<device>function <func>.
LCD Message Bus fatal error on bus <bus> device <device> function
<func>. Power cycle system.
Details System performance may be degraded, or system may fail to
operate.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
118