Dell R420xr Personal Computer User Manual


 
Error Code Message Information
Action Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see Getting Help.
CPU0005
Message CPU <number> configuration is unsupported.
LCD Message CPU <number> configuration is unsupported. Check CPU or
BIOS revision.
Details System is unable to boot or may run in a degraded state.
Action Review the technical specifications for supported processor
types.
CPU0010
Message CPU <number> is throttled.
Details The CPU is throttled due to thermal or power conditions.
Action Review system logs for power or thermal exceptions.
CPU0023
Message CPU <number> is absent.
LCD Message CPU <number> is absent. Check CPU.
Action Verify processor installation. If present, re-seat the
processor.
CPU0204
Message CPU <number> <name> voltage is outside of range.
LCD Message CPU <number> <name> voltage is outside of range. Re-seat
CPU.
Details Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
Action
1. Turn off the system and remove input power for one
minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see Getting Help.
CPU0700
Message CPU <number> initialization error detected.
LCD Message CPU <number> initialization error detected. Power cycle
system.
Details System BIOS was unable to initialize the processor.
113