Dell R420xr Personal Computer User Manual


 
Error Code Message Information
PCI1342
Message A bus time-out was detected on a component at slot
<number>.
Details System performance may be degraded, or system may fail to
operate.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1348
Message A PCI parity error was detected on a component at slot
<number>.
LCD Message PCI parity error on slot <number>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to
operate.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1360
Message A bus fatal error was detected on a component at slot
<number>.
LCD Message Bus fatal error on slot <number>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to
operate.
Action Cycle input power, update component drivers, if device is
removable, reinstall the device.
PDR0001
Message Fault detected on drive <number>.
LCD Message Fault detected on drive <number>. Check drive.
Details The controller detected a failure on the disk and has taken
the disk offline.
Action Remove and re-seat the failed disk. If the issue persists, see
Getting Help.
PDR1016
Message Drive <number> is removed from disk drive bay <bay>.
LCD Message Drive <number> removed from disk drive bay <bay>. Check
drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue
persists, see Getting Help.
119