Dell R420xr Personal Computer User Manual


 
Error Code Message Information
LCD Message System power demand exceeds capacity. System halted.
Details The system halted because system power exceeds capacity.
Action Review system configuration, upgrade power supplies or
reduce system power consumption.
RFM1008
Message Failure detected on Removable Flash Media <name>.
LCD Message Removable Flash Media <name> failed. Check SD Card.
Details An error was reported during a SD card read or write.
Action Reseat the flash media. If the problem persists, see Getting
Help.
RFM1014
Message Removable Flash Media <name> is write protected.
LCD Message Removable Flash Media <name> is write protected. Check
SD Card.
Details The card is write-protected by the physical latch on the SD
card. A write-protected card cannot be used.
Action If unintended, remove the media and disable write
protection.
RFM1201
Message Internal Dual SD Module redundancy is lost.
LCD Message Internal Dual SD Module redundancy is lost. Check SD Card.
Details Either one or both the SD cards are not functioning properly.
Action See Getting Help.
RFM2001
Message Internal Dual SD Module <name> is absent.
LCD Message Internal Dual SD Module <name> is absent. Check SD Card.
Details The SD card module is not detected or not installed.
Action If unintended, reinstall the SD module.
RFM2002
Message Internal Dual SD Module <name> is offline.
Details The SD card module is installed but may be improperly
installed or configured incorrectly.
Action Reinstall the SD module.
RFM2004
Message Failure detected on Internal Dual SD Module <name>.