Denso BHT-6000 Scanner User Manual


 
141
Chapter 5. Handling the CU-6000 (Option)
5.5.2 Ni-MH Battery Cartridge Alone
WARNING
Never use the CU-6001 for charging anything
other than the specified battery cartridges.
Doing so could cause heat, battery-rupture, or
fire.
CAUTION
Handling the battery cartridge
Never charge a wet or damp Ni-MH battery
cartridge.
Doing so could cause the batteries to break,
generate heat, rupture, or burn.
Do not insert or drop foreign materials such as
metals or anything inflammable through the
openings (vents or battery cartridge slot) into
the CU-6000.
Doing so could result in a fire or electrical shock.
The CU-6001 can charge Ni-MH battery cartridges in either of the following two ways:
- Fully discharging and then charging* [ 1 ]
- Charging only [ 2 ]
* Fully discharging and then charging batteries
can prevent "Memory Effect" as described at
the beginning of Section 5.5.
To select [ 1 ], first power on the CU-6001 and then load a Ni-MH battery cartridge into
it. To select [ 2 ], first load a Ni-MH battery cartridge into the CU-6001 and then power
it on.
Ni-MH battery
cartridge