Denso BHT-6000 Scanner User Manual


 
51
Chapter 2. Getting Started the BHT-6000 and System Mode
SET SERIAL No.
< OPTICAL >
1:ON 2:OFF
Selecting the "1:SERIAL No." on the SET PROTO-
COL menu calls up the screen shown at left.
Select whether or not the system should add serial
numbers to data blocks, by using the numerical
keys or F5 and F6 keys. Then press the ENT
key.
To return to the SET PROTOCOL menu, press the
C key.
Selecting the "2:H.PARITY" on the SET PROTOCOL
menu calls up the screen shown at left.
Select whether or not the system should add a
horizontal parity, by using the numerical keys or
F5 and F6 keys. Then press the ENT key.
To return to the SET PROTOCOL menu, press the
C key.
Selecting the "3:LINKUP TIME" on the SET PROTO-
COL menu calls up the screen shown at left.
Select the timeout length (in seconds) to be ap-
plied when a link is to be established, by using the
numerical keys or F5 and F6 keys. Then press
the ENT key.
To return to the SET PROTOCOL menu, press the
C key.
Selecting the "4:FIELD SPACE" on the SET PROTO-
COL menu calls up the screen shown at left.
Select whether space codes in the tail of a data
field should be ignored or handled as data, by
using the numerical keys or F5 and F6 keys.
Then press the ENT key.
To return to the SET PROTOCOL menu, press the
C key.
SET H.PARITY
< OPTICAL >
1:ON 2:OFF
SET FIELD SPACE
< OPTICAL >
1:Ignore
2:Data
SET LINKUP TIME
< OPTICAL >
1:30 4:120
2:60 5:None
3:90