Emerson RTM-ATCA-7150 Power Supply User Manual


 
Installation of the RTM-ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
40
2.5 Installation Preparations
The installation preparations process includes:
z check the installation environment
z wear the ESD-preventive wrist strap
z remove the blank filler panels
z unpack and check the RTM-ATCA-7150 suite
2.5.1 Wearing the ESD-Preventive Wrist Strap
Module Damage
z Electrostatic discharge can damage circuits or shorten their life.
z The ESD-preventive wrist strap prevents only the static electricity on your body from
damaging the blade. To prevent the static electricity on your clothes, it is recommended
to wear the antistatic clothes. Additionally, you have to make sure that the cabinet and
shelf are properly grounded - for details, refer to the corresponding system
documentation.